Please use this identifier to cite or link to this item: http://hdl.handle.net/2381/33449
Title: High mass accuracy assay for trimethylamine N-oxide using stable-isotope dilution with liquid chromatography coupled to orthogonal acceleration time of flight mass spectrometry with multiple reaction monitoring
Authors: Heaney, Liam M.
Jones, Donald J. L.
Mbasu, Richard J.
Ng, Leong L.
Suzuki, Toru
First Published: 14-Nov-2015
Publisher: Springer Verlag
Citation: Analytical and Bioanalytical Chemistry (Online First)
Abstract: Trimethylamine N-oxide (TMAO) has attracted interest as circulating levels have reported prognostic value in patients with cardiovascular conditions, such as heart failure. With continual advances in accurate mass measurements, robust methods that can employ the capabilities of time of flight mass spectrometers would offer additional utility in the analysis of complex clinical samples. A Waters Acquity UPLC was coupled to a Waters Synapt G2-S high-resolution mass spectrometer. TMAO was measured in plasma by stable-isotope dilution-hydrophilic interaction liquid chromatography-time of flight mass spectrometry with multiple reaction monitoring (LC-ToF-MRM). Two transitions were monitored: m/z 76.1 to 58.066/59.073 and m/z 85.1 to 66.116/68.130. The method was assessed for linearity, lower limits of detection and quantitation, and reproducibility. A selected cohort of patients with systolic heart failure (SHF; n = 43) and healthy controls (n = 42) were measured to verify the assay is suitable for the analysis of clinical samples. Quantitative analysis of TMAO using LC-ToF-MRM enabled linearity to be established between 0.1 and 75 μmol/L, with a lower limit of detection of 0.05 μmol/L. Relative standard deviations reported an inter-day variation of ≤20.8 % and an intra-day variation of ≤11.4 % with an intra-study quality control variation of 2.7 %. Run times were 2.5 min. Clinical application of the method reported that TMAO in SHF was elevated compared to that of healthy controls (p < 0.0005). LC-ToF-MRM offers a highly selective method for accurate mass measurement of TMAO with rapid and reproducible results. Applicability of the method was shown in a selected cohort of patient samples.
DOI Link: 10.1007/s00216-015-9164-6
ISSN: 1618-2642
eISSN: 1618-2650
Links: http://link.springer.com/article/10.1007%2Fs00216-015-9164-6
http://hdl.handle.net/2381/33449
Version: Post-print
Status: Peer-reviewed
Type: Journal Article
Rights: Copyright © 2015, Springer Verlag. All rights reserved. The final publication is available at Springer via http://dx.doi.org/10.1007/s00216-015-9164-6
Description: The file associated with this record is under a 12-month embargo from publication in accordance with the publisher's self-archiving policy, available at http://www.springer.com/gp/open-access/authors-rights/self-archiving-policy/2124. The full text may be available through the publisher links provided above.
Appears in Collections:Published Articles, Dept. of Cardiovascular Sciences

Files in This Item:
File Description SizeFormat 
TMAO Method Accepted Manuscript.docxPost-review (final submitted)622.5 kBUnknownView/Open
TMAO Method Accepted Manuscript.pdfPost-review (final submitted)2.21 MBAdobe PDFView/Open


Items in LRA are protected by copyright, with all rights reserved, unless otherwise indicated.