Title: Dynamic Behavior of Rotors during Human Persistent Atrial Fibrillation as observed using Non-Contact Mapping
Authors: Dastagir, Nawshin
Almeida, Tiago P.
Li, Xin
Vanheusden, F. J.
Chu, Gavin S .
Stafford, Peter J.
Ng, G. André
Schlindwein, Fernando S.
First Published: 2-Mar-2017
Presented at: CinC 2016, Computing in Cardiology 2016, Canada
Start Date: 11-Sep-2016
End Date: 14-Sep-2016
Publisher: IEEE
Citation: Computing in Cardiology 2016, 43, pp. 241-244
Abstract: Rotors have been related to atrial fibrillation (AF) maintenance. We analyzed the behavior of rotors in persistent AF (persAF) utilizing a novel non-contact methodology and compared this to real time dominant frequency (DF) analysis. 2048 noncontact virtual unipolar atrial electrograms (VEGMs) were collected simultaneously (EnSite Array, St. Jude Medical) from 10 persAF patients (duration: 34 ± 25 months) undergoing left atrial (LA) ablation. After QRST-removal, FFT was used to identify the global DF of the LA (range 4 - 10 Hz; 1 s time-window; 50 % overlap; highest DF (HDF) (DF -0.25 Hz); up to 20 s/patient). The organization index (OI) was measured and phase was found via Hilbert-transform. Phase singularities (PSs) were tracked and were categorized according to their lifespan into short (lifespan <100 ms) and long lived (rotors) (lifespan ≥100 ms). A total of 4578 PSs were tracked. 5.05 % (IQR: 2.75 ~ 30.25 %) of the tracked PSs were long-lived and were observed in 11 % (IQR: 2.75 ~ 17.5 %) of the windows. The windows with rotors showed significantly higher HDF (mean ± SD, 8.0 ± 0.43 Hz vs 7.71 ± 0.50 Hz, p< 0.0001) and lower OI (0.76 ± 0.04 vs 0.79 ± 0.03, p< 0.0001) when compared with the short-lived PSs windows. During persAF, the LA showed distinct behaviors as characterized by rotors. Often, no rotors were observed during sustained AF and, when present, the rotors continually switched between organized and disorganized behaviors. Long-lived rotors correlated with higher atrial rates. Our results suggest that rotors are not the sole perpetuating mechanism in persAF.
ISSN: 2325-8861
eISSN: 2325-887X
Links: http://ieeexplore.ieee.org/document/7868724/
http://hdl.handle.net/2381/38507
Version: Publisher Version
Status: Peer-reviewed
Type: Conference Paper
Rights: Copyright © 2016, IEEE. Deposited with reference to the publisher’s open access archiving policy.
Appears in Collections:Conference Papers & Presentations, Dept. of Engineering

Files in This Item:
File Description SizeFormat 
nd139_CinC'16_final.pdfPost-review (final submitted author manuscript)271.83 kBAdobe PDFView/Open


Items in LRA are protected by copyright, with all rights reserved, unless otherwise indicated.